Search found 19 matches
- Tue Feb 04, 2014 9:35 pm
- Forum: Testing/Bug Reports
- Topic: Multicamera Camera Issues
- Replies: 10
- Views: 11750
First take after a format
<t>Hi Duka, Another related performance issue to formating the CF cards of my connected D800 cameras is that the first shot after formating when transfer to PC is selected causes the cameras to hang for a minute or two. It looks like they are polling / re-connecting to DigiCam. Each camera gets a r...
- Tue Feb 04, 2014 9:24 pm
- Forum: Feature requests
- Topic: Download window
- Replies: 1
- Views: 2140
Download window
Hi Duka, Would it be possible to make the download window stay open or automatically re-open after a format of connected cameras is completed? Currently it closes upon completion of formating cameras.
- Sat Feb 01, 2014 10:38 am
- Forum: Testing/Bug Reports
- Topic: Multicamera Camera Issues
- Replies: 10
- Views: 11750
Log attached to first post
Hi Duka, the log file is attached to the first post in this thread.
- Sat Feb 01, 2014 1:09 am
- Forum: Testing/Bug Reports
- Topic: Multicamera Camera Issues
- Replies: 10
- Views: 11750
Format CF cards
<t>Thanks Duka, I'll upload the log files when I'm in the office on Monday. I have work arounds for some of the issues. Specifically I found unplugging the USB cable of a 'hung' camera and then ru-plugging it whilst leaving DigiCam running, enabled the camera to write out the missing frames from its...
- Fri Jan 31, 2014 6:23 pm
- Forum: Testing/Bug Reports
- Topic: Multicamera Camera Issues
- Replies: 10
- Views: 11750
A quick update re. Use Parallel File Transfer enabled.
<t>A quick update re. Use Parallel File Transfer enabled. When a camera 'hangs' and stops writng it's buffer out to PC, it looks like the missing images are still in the frame buffer.You can tell this by the fact the 'r' value (the remaining available image space in the camera's buffer, which can be...
- Fri Jan 31, 2014 5:49 pm
- Forum: Testing/Bug Reports
- Topic: Multicamera Camera Issues
- Replies: 10
- Views: 11750
Multicamera Camera Issues
<t>Hi Duka, I've been doing some additional tests using 6 x Nikon D800's, all connected via USB 3.0 and running release candidate 2 in a Win7 64bit environment.I have found the following bugs / issues:Camera status upon launch of DigiCam control - With all 6 cameras connected to 1 computer, cameras ...
- Mon Jul 01, 2013 10:20 am
- Forum: Testing/Bug Reports
- Topic: Exposure & Capture Control
- Replies: 2
- Views: 3345
Version 1.0.586
Hi Duka, that has fixed the problem, the second exposure panel is now updating.
Thanks
Thanks
- Mon Jul 01, 2013 10:18 am
- Forum: Feature requests
- Topic: Counter Padding
- Replies: 4
- Views: 3823
Version 1.0.586
Hi Duka, I've run the latest version but can't find how to adjust the counter padding? It look like it is still 5 digits e.g. 00001
- Fri Jun 21, 2013 6:11 pm
- Forum: Feature requests
- Topic: Counter Padding
- Replies: 4
- Views: 3823
Counter Padding
Duka, would it be possible to enable changing the amount of padding in the Counter function ($C) ?
Currently it's default is five digits e.g. 00001
Specifically three digits would be super handy e.g 001
What do think?
Currently it's default is five digits e.g. 00001
Specifically three digits would be super handy e.g 001
What do think?
- Thu Jun 20, 2013 4:03 pm
- Forum: Testing/Bug Reports
- Topic: Exposure & Capture Control
- Replies: 2
- Views: 3345
Exposure & Capture Control
<t>Hi Duka,<br/> <br/> Just found that the second pane of exposure and capture control - Image Size, Auto ISO, Lock etc - is not connected to the "Use As Master" button, so these settings do not update on all connected cameras. Is there any chance of enabling these settings for multi-cam?<br/> <br/>...